Description
Product Features
Produces a maximum of 7000 gallons per day. When sizing ensure system is capable of twice the predicted usage for best performance and longevity
Multi Color LED Indicator Status, Pre-treatment lockout, tank level input, and low pressure monitoring and alarm
20" Big Blue 5 µ sediment, carbon block, 1µ sediment prefilters protect system components
High pressure multi-stage pump provides optimum operating pressure for maximum membrane efficiency
Permeate and concentrate flow meters to monitor and adjust system performace
Built in TDS meter monitors membrane effeciency and system output
Allows for adjustment of concentrate to suit application
Provides at a glance monitoring of pressure drop though prefilters, an indicator of filter change requirements
Provides a high quality, light weight base for ease in placing the system
Quick connect fittings with locking clips make system maintenance simple
Product Description
The Flexeon (formerly Titan) line of commercial RO systems provide purified water in a variety of sizes for any need, from small systems for lab purposes, mid-size systems for home purification, or large systems for large scale bottling operations. High quality construction ensures long lasting operation and low replacement costs
Large scale reverse osmosis is the key solution to providing high volumes of purified water. These systems can provide the water needed for exacting laboratory tests, high quality spot free rinses for car washes, and any other application where pure water is essential.
Reverse osmosis is also the key to eliminating high sodium and/or TDS levels in the water. Typical filtration is unable to remove these troublesome water problems, but the Flexeon systems are capable of reducing sodium and TDS levels by up to 98%! That makes these systems ideal for homes where sodium intake is closely monitored, or homes with excessive TDS levels.
For peak performance we recommend using high quality atomspheric storage tanks and top of the line Grundfos inline pressurization pumps, contact us for a great deal on a complete setup.
More Info
Flexon CT Series Spec Sheet -
Flexeon CT Series Manual -
More on commercial/whole house RO systems
Commercial RO systems are typically used when high volumes of pure water are needed (such as spot free rinse cycles at car washes) or for situations where RO is the only way to treat the problem (such as homes with high sodium and/or TDS). Whole house RO systems are NOT designed as a fix-all solution. Iron and hardness should be removed before entering the RO system (see system operation limits below).
Typical setups for Flexeon systems include a storage tank and pump for delivering the treated water back into the house. The system is installed after the pressure tank on applications using a well. Important: When sizing a commercial RO system, the system needs to be rated for at least twice the planned usage rate (e.g. if planned usage is 500 gallons per day, the ideal system would be 1000 GPD or larger). This prevents premature wear on the system and can significatly decrease long term maintenance costs.
Maximum Feed Temperature | 105°F (40.96°C) | Maximum Free Chlorine | 0 ppm | |
Minimum Feed Temperature | 40°F (4.44°C) | Maximum TDS | 2000 ppm | |
Maximum Ambient Temperature | 120°F (48.89°C) | Maximum Hardness | 15 GPG (256.5 ppm) | |
Minimum Ambient Temperature | 35°F (1.66°C) | Maximum pH (Continuous) | 11 | |
Maximum Feed Pressure | 85 psi (5.86 bar) | Minimum pH (Continuous) | 3 | |
Minimum Feed Pressure | 150 psi (10.34 bar) | Minimum pH (Cleaning 30 Min.) | 2 | |
Maximum SDI Rating | <3 SDI | |||
Maximum Turbidity | 1 NTU | |||
Minimum Feed Temperature | 40°F (4.44°C) | Maximum TDS | 2000 ppm |